Appendix B: Technical & Electrical Glossary¶
This glossary explains key terms from emergency management, electrical engineering under DIN VDE, and system architecture of Stromnetz Pro.
A¶
- AES-256 Column Encryption: Cryptographic protection of sensitive database fields (commanders, exact addresses, notes) in the local SQLite/Room database using 256-bit keys.
- Apparent Power (\(S\) in kVA): Vector sum of active power \(P\) and reactive power \(Q\) (\(S = \sqrt{P^2 + Q^2}\)). Represents total power drawn from the generator.
- Active Power (\(P\) in kW): Electrical power converted into real work, heat, or light (\(P = S \cdot \cos\varphi\)).
- Audit Log: Chronological log of all safety-critical switching actions, alarms, shift changes, and pairings in the app.
C¶
- CEE Connectors: Internationally standardized industrial connectors:
- CEE 16A (Red): 400 V 3-phase AC up to 11 kW.
- CEE 32A (Red): 400 V 3-phase AC up to 22 kW.
- CEE 63A (Red): 400 V 3-phase AC up to 44 kW.
- CEE 16A (Blue): 230 V single-phase AC.
- Cosine Phi (\(\cos\varphi\) / Power Factor): Ratio of active power \(P\) to apparent power \(S\). For 3-phase generators and motors, calculated with default \(\cos\varphi = 0.8\).
D¶
- Delta Update (Incremental Sync): Data sync technique in P2P mesh exchanging only modified database records to conserve battery and radio bandwidth.
- Derating: Mathematical reduction of cable current capacity under adverse conditions (e.g. heat trapping in coiled drums).
- DGUV Regulation 3: Accident prevention regulation for electrical systems and equipment in operations.
- DIN VDE 0100-520: Standard governing low-voltage electrical installations; specifies maximum permissible voltage drop of 3.0%.
E¶
- ECDH (Elliptic Curve Diffie-Hellman): Key exchange protocol (secp256r1) allowing two smartphones in the field to establish an AES-256 session key without internet.
H¶
- H07RN-F: Standard heavy-duty rubber-sheathed flexible cable. Standard field cable due to mechanical durability, oil, and weather resistance.
- Gloves Mode: Accessibility mode with enlarged touch targets (at least 64 dp) and wide spacing for heavy protective gloves (DIN EN 388).
- Hands-Free Voice Control: 100% offline-capable voice assistant enabling touchless control (grid topology, phase switching, refueling, reports) around generators with work gloves.
I¶
- Inrush Current: Brief initial current drawn by electric motors (e.g. pumps) at startup, up to 3 to 6 times rated current.
- InventoryManager: Internal engine reconciling target vehicle equipment lists with active field deployments.
- IT Grid: Isolated grid without direct grounding of active conductors, typical for portable generators with insulation monitoring.
L¶
- Last-Write-Wins (LWW): Conflict resolution mechanism merging concurrent offline edits based on timestamps.
- Load Curve: Graphical representation of active/apparent power draw over mission duration in PDF reports.
M¶
- MBTiles: Open file format for offline map tile archives. Enables offline tactical mapping without cellular network.
N¶
- Nearby Connections: Framework enabling wireless ad-hoc mesh networks via Bluetooth Low Energy (BLE) and Wi-Fi Direct without external routers.
- Neutral Point Shift: Dangerous voltage shift in 3-phase networks caused by extreme unbalance or broken neutral conductors. Single-phase loads can receive overvoltage (up to 400 V) and suffer damage!
P¶
- P2P Mesh: Decentralized radio network between smartphones/tablets without cell towers or internet.
- Phase Unbalance: Unequal current loading across 3-phase generator windings L1, L2, and L3. Differences exceeding 30% risk rotor overheating.
R¶
- RCD (Residual Current Device): Safety device disconnecting power within milliseconds upon detecting leakage currents to ground (typically 30 mA).
- Reactive Power (\(Q\) in kvar): Power oscillating between generator and load to establish magnetic fields in motors or transformers without performing net work.
S¶
- Safe Auto-Approve: Intelligent mesh policy auto-approving non-critical actions while requiring manual commander sign-off for actions risking overload or voltage drop.
- Single Line Diagram (SLD): Standardized single-line schematic diagram (DIN EN 60617) representing the entire temporary power grid for plotters and command staff.
- Stealth Mode: Security function disabling all wireless interfaces (BLE/Wi-Fi) for radio-silent operations.
T¶
- TN-S Grid: Grid grounding scheme with separate protective earth (PE) and neutral (N) conductors and grounded neutral point at generator. Standard for large generator net feeds.
V¶
- Voltage Drop (\(\Delta U\)): Voltage loss between generator and consumer caused by cable resistance. Maximum allowed is 3.0%.
W¶
- Wake-Word: Trigger phrase such as "Hey Stromapp", "Hallo Stromapp", or "Sprachbefehl starten" waking continuous foreground voice recognition to receive commands.